Wednesday, 25 June 2008

HRX TCPIP Connected Fire Alarm Printer

It is possible to connect a serial laser printer to an HRX3000 / 5000 via a TCP/IP network.
The process involves the use of a pair of RS232-Network converters, one at the HRX and one at the printer. The document below shows connection and configuration information for use with an HRX5000.

downloads/HRX5000_FireAlarm_Printer_TCPIP_Connections.pdf

Labels: , , , ,

Tuesday, 24 June 2008

HRX Hosting HandPunch

A new adaptation has been developed which combines the extended features of the HRX5000 with the biometric HandPunch terminal. The HandPunch is connected to the HRX terminal via an RS232 serial cable. All of the enrolment and clocking in/out is conducted at the HandPunch in the normal way. However, it is the HRX that actually records the clockings and also sends a verification message to the display on the HandPunch.

The Focus software collects the clocking transactions from the HRX terminal. Because employee details and transactions are stored on the HRX, the following features are therefore available:

*Automated Fire Alarm evacuation reporting to up two dedicated hardwired printers.

*Access Control of up to two doors.

*Factory Bell triggering.

Indeed, rather than using an HRX5000, an HRX Access Controller would provide the same functionality and would be more cost effective.

If multiple HandPunch terminals are required, each HandPunch would connect to its HRX host terminal. The HRX master/slave method could be used if preferred.

We are looking forward to our first implementation of this kind. Any comments are very welcome.

Labels: , , , ,

Wednesday, 11 June 2008

New Focus Fire Alarm Evacuation Feature

A new feature has been included in Focus Pro version 2.532, which is available when used in conjunction with the latest version of firmware for the HRX3000 and HRX5000 terminals.

Both the HRX3000 and HRX5000 have an input terminal for connection to a fire alarm panel or a manually operated button. The input is used to trigger an evacuation report be sent to a hardwired serial printer.

The newly introduced feature means the input can now also trigger a 'fire alarm transaction' within the HRX terminal. Just like a clocking in or out transaction, the fire alarm transaction is collected by the Focus Watch Service. As soon as the fire alarm transaction is received, the Watch Service automatically generates the Focus software based fire alarm report. This report can of course be pre-configured to be sent to multiple printers across the network of an organisation.

Although we consider the ability to produce a fire alarm evacuation directly from the HRX terminal to be a really powerful feature which is not found in many other T&A systems, we also recognise that different companies have different needs and requirements. Hopefully this new functionality will benifit both new and existing Focus Pro customers.

Labels: ,